Showing results: 301 - 315 of 486 items found.
-
Magtrol Inc.
Magtrol's Load Monitoring Units are used for measuring load, force and weight from signals generated by strain gauge transducers. Specifically designed for use with Magtrol's Load Measuring Pins and Load-Force-Weight Sensors, the LMU Series provides excitation voltage while conditioning the bridge output signal. Each unit contains DIP-switches and jumpers for greater flexibility and complete adaptability
-
Analog Devices Inc.
Analog Devices signal conditioning ICs, together with linear variable differential transformers (LVDTs), can be used to convert mechanical position to a dc voltage. The IC provides both the excitation for the LVDT and the output conversion to dc level with a user selectable gain. ADI LVDT signal conditioners are available to interface with a wide range of LVDTs, including half bridge and standard 4- and 5-wire.
-
786328-01 -
NI
The RM-26999 is a rack-mounted, signal conditioning device that connects to several simultaneous-sampling multifunction I/O devices for power measurements. It features four voltage input channels with peak voltages up to 2,000 V and four … current transducer ports for current measurements. The current transducer ports are optimized for flux-gate transducers by providing all the power, communication, and signal lines required for accurate measurements.
-
Tektronix, Inc.
The Tektronix BERTScope® and PatternPro® families provide a range of signal conditioning and BER test solutions from 1.5 Gb/s to 40 Gb/s on 1-4 channels and deliver the test and measurement industry’s broadest serial communications test portfolio of Bit Error Rate Tester products.
-
Dewesoft d.o.o.
IOLITE LX - Embedded Data Acquisition SystemIOLITE LX is an embedded data acquisition system based on a low power Linux based ARM processor with open architecture being able to act like a data logger, real-time system, and signal conditioning frontend, all at the same time.
-
USBPGF-S1 -
Alligator Technologies
Single Channel USB Programmable Anti-Alias Low-Pass Filter and Instrumentation Amplifier for Signal Conditioning in Data Acquisition Systems. Differential or single ended input. 10Vmax Signal Input and Output with input protection up to 40V. Software-programmable instrumentation amplifier gains of 1 to 1000.
-
EMIC Corporation
The principle of the eddy current is applied to measure the distance without contacting an object. This measuring method is widely used in the industry for detecting abnormal vibrations of rotating shafts or ironwork in a production in line. The highly accurate signal conditioning for providing the analog voltage being linearly proportional to displacement can be made easy.
-
Dexter Research Center, Inc.
A low cost solution for non-contact temperature measurements. The sensor is integrated with signal conditioning that reliably produces a calibrated linear digital output in a plug-and-play package having many options. Programmable outputs and flexible power requirements yield a turnkey solution for medical, consumer, commercial and industrial applications.
-
(UDAS/USB2250) -
Validyne Engineering
The Universal Data Acquisition System(UDAS) Sensor Interface provides real world data acquisition for your PC via the USB port. 16 sensor inputs in any mix or combination are accepted by the UDAS. No external signal conditioning is required. The UDAS includes configuration and data acquisition software.
-
ILA -
Dwyer Instruments Inc.
10:1 Distance to Target Ratio, 32 to 932F. Dwyer Series ILA Non-Contact Sensors, measure temperatures from 32 to 932F (0 to 500C) and provide a linear 4 to 20 mA, 0 to 5 VDC or thermocouple output. The 2-wire signal is compatible with almost any indicator, controller, recorder, data logger, etc., without the need for special interfacing or signal conditioning.
-
Jinan Testing Equipment IE Corporation
TE electronic calibration module provides an easy way to calibrate load cell or extensometer and signal conditioning electronics without using a mechanical calibrator. It enables performing on-site electrical calibration and easy to periodically “spot check”, which will help ensure that the load cell and the extensometer and electronics are calibrated correctly.
-
V450 -
Highland Technology, Inc.
The V450 is a 16-channel 24-bit VME isolated analog-to-digital converter module which can acquire a wide range of DC voltages, including thermocouple readings with automatic cold junction compensation. Each channel is independently isolated with it's own A/D converter, signal conditioning, input protection circuits, and test relay.
-
UPC2100 -
Validyne Engineering
The UPC2100 PCI Sensor Interface card provides real-world data acquisition and control for your PC. Up to 16 sensor inputs in any mix or combination are accepted by the UPC2100. No external signal conditioning is required. The UPC2100 includes configuration and data acquisition software and is compatible with C#, .NET, C++, Visual Basic, LabView.
-
Allegro MicroSystems
Easy to use, flexible, and reliable. Allegro’s sensor interface ICs offer accurate and fast output for signal conditioning in a wide range of applications, from electric vehicle HVAC systems to transmission oil pressure. Our innovative algorithms deliver robust EMC performance and provide critical diagnosticsthat support automotive safety.
-
Columbia Research Laboratories
Columbia's Integrated Accelerometers are completely self-contained vibration measuring systems having a built-in amplifier within the housing. Low output impedance allows operation directly into standard readout equipment without auxiliary signal conditioning. This type of accelerometer must be powered by a constant current power supply like Columbia's model 5421.